November 04, 2020
Graphite sulfuric acid diluter can be used directly
Cracking and transparency. C-276 is expensive but has good heat exchange effect
and long use time. The tube side is 316L stainless steel, the tube shell is
ordinary carbon steel, the tube side uses a mixture of sulfuric acid and nitric
acid, and the shell side uses cooling water, which is quite good.Question: What
material is the best choice for the sulfuric acid and acetic acid resistant
materials of the heat exchanger tubes? Graphite and fluoroplastic
materials can be used. The material resistant to sulfuric acid and
acetic acid is preferably Hastelloy. 316L ptfe
coated fiberglass adhesive tape Manufacturers stainless steel is sufficient,
because our company also has such a heat exchanger.
For example, the Alfa Laval
plate heat exchanger widely used in the sulfuric acid industry basically uses
Hastelloy C276, and the boiler flue gas desulfurization tower uses 316L, which
is corrosive. It should not be difficult to generalize. Possibly, Hastelloy C276
is used in order to avoid dilute acid corrosion; the acetic acid distillation
tower has a certain temperature, 316L may be corroded, and G30 grade Hastelloy
is used, such as Jiangsu Thorpe Group.
Graphite heat exchanger can be
used. Therefore, it is recommended for key parts. Fluoroplastic heat exchanger
is suitable for nitric acid, hydrochloric acid, sulfuric acid, acetic acid,
phosphoric acid, hydrofluoric acid, aqua regia, chromic acid, organic acid,
ammonium bifluoride, caustic soda, potassium hydride, chlorine (dry) chlorine
(gas-liquid), inorganic Heating, cooling, evaporation, concentration and
crushing of any solution in salt and electroplating surface treatment. Stainless
steel is fine for acetic acid. If it is concentrated sulfuric acid dilution
cooling, graphite sulfuric acid diluter can be used directly, which can dilute
sulfuric acid and cool it to output below 45 degrees. For high-concentration
sulfuric acid heat exchangers, the best is Kazakhstan Alloy (C-276).
The acetic acid resistant material of the heat exchanger tube of the heat
exchanger is best to use titanium or zirconium, but the production cost is
higher. Answer 7: I think it can be based on the operating temperature and
pressure of the heat exchanger, the temperature difference between the inside
and outside of the heat exchange tube, and the nature of the fluid (what
substance and concentration), according to the relevant standards, considering
the material cost, processing cost, and service life, and comprehensive
consideration Select materials. The performance of fluoroplastic heat exchanger:
The heat exchanger material made of PFA, FEP, PVDF pipes is more excellent than
polytetrafluoroethylene (PTFE) heat exchanger material, and has higher thermal
stability, flexibility and resistance.
First of all, the concentration
and temperature of the acid must be clarified, so that the right material can be
selected. Do you require both sulfuric acid and acetic acid resistance
or separate requirements? Also, for sulfuric acid, it depends on the
concentration and temperature
Posted by: meshbelt at
02:00 AM
| No Comments
| Add Comment
Post contains 476 words, total size 3 kb.
<< Page 1 of 1 >>
9kb generated in CPU 0.0053, elapsed 0.0233 seconds.
32 queries taking 0.0191 seconds, 43 records returned.
Powered by Minx 1.1.6c-pink.
32 queries taking 0.0191 seconds, 43 records returned.
Powered by Minx 1.1.6c-pink.